EERI Innovation Showcase Session 2

EERI Innovation Showcase Session 2

Title history
  • EERI Innovation Showcase Session 2 — observed on 20261119-1723 UTC (YouTube)
🎙 EERI (presented by John Osteraas, Ari Ahrabi, Marlon Aguero) 👥 118K 📅 November 19, 2026 ⏱ 57 min 👁 12 📄 expert opinion 🧭 2026-11-19
Available in: English (current) Français

Keywords

collapse shadowpost-earthquake cordoninganchors quality assuranceseismic monitoringadhesive anchors

Summary

The webinar presents three technical talks. First, John Osteraas of Exponent discusses FEMA P-2055-2, which provides improved guidelines for cordoning off buildings damaged by earthquakes. He critiques the old 1.5x building height rule and recommends a 1x height initial cordon, refined based on structural system and damage type. He illustrates with case studies, including the 1989 Marina District collapses and a recent New York City incident. Second, Ari Ahrabi from Hilti Canada addresses quality assurance for post-installed anchors and reinforcing bars. He highlights the 2006 Boston I-90 tunnel collapse caused by adhesive anchor failure and a field study showing poor installation practices without proper inspection. He outlines ACI 355 requirements, including inspection and proof loading, emphasizing the need for certified installers and verification. Third, Marlon Aguero of Kinemetrics presents a bridge monitoring project in Mexico, detailing seismic health monitoring systems and their role in post-earthquake assessment. The talks collectively emphasize improved safety measures, quality control in construction, and real-time monitoring for resilience.

162 words

Critical Evaluation

Value of the Information & Strength of the Argument

The presentations provide valuable, actionable information for earthquake engineering professionals. The cordoning guidelines are evidence-based, using collected collapse data and case studies, and successfully argue for a more nuanced approach than the previous conservative rule. The QA talk effectively uses the Boston tunnel tragedy to demonstrate real-world consequences and presents a compelling case for rigorous inspection. The argumentation is solid, relying on recognized standards and field studies. The bridge monitoring talk offers practical insights into instrumentation and data interpretation. Overall, the content is practical, well-structured, and supported by authoritative references, though it lacks critical discussion or comparison with alternative methods.

Scientific Rigor, Source Quality, Title Accuracy

The presentations cite authoritative sources: FEMA documents, ACI 355 standards, and NTSB reports. The speakers reference specific guidelines and research studies, lending credibility. However, no external links are provided in the description, and the sources are mentioned only verbally. The title adequately represents the content, focusing on innovation and technical showcases. The scientific rigor is high due to the expertise of the speakers and the use of established engineering standards, though the lack of a formal peer-review process and absence of critical evaluation slightly reduce the overall reliability.

203 words

Title / Content Match

The title is generic but accurately reflects the technical innovation showcase content with three distinct engineering presentations.

Quality & Reliability

8/10

Presented by recognized experts from Exponent, Hilti, and Kinemetrics, with references to FEMA and ACI standards. However, the content is purely prescriptive without critical evaluation or alternative viewpoints.

Chapters

Cited Sources

  • FEMA P-2055-2 Collapse Shadow and Post-Earthquake Cordoning — Described in the first presentation as the basis for improved cordoning guidelines.
  • ACI 355.2, 355.4, and 355.5 — Mentioned in the second presentation as qualification standards for post-installed anchors and reinforcing bars.
  • NTSB Report on the Boston I-90 tunnel collapse — Referenced in the second talk as the case study of adhesive anchor failure.

Contribution & Novelties

The webinar presents novel contributions to earthquake engineering practice: refined cordoning recommendations based on collapse mechanisms, an emphasis on quality assurance for anchors, and detailed case studies of bridge monitoring. It provides practical, field-tested guidance that can directly influence post-disaster response and construction quality. The innovation lies in combining research with real-world applications and fostering awareness of less-discussed aspects like inspection of post-installed elements.

Pour aller plus loin :

  • FEMA Earthquake Risk Management — Provides access to FEMA guidelines, including relevant earthquake publications.
  • ACI (American Concrete Institute) — Official site for ACI standards, including 355 series on post-installed anchors.
  • Big Dig ceiling collapse (Wikipedia) — Detailed background on the 2006 Boston tunnel collapse that motivated changes in anchor practice.

119 words

Radar Profile

The radar profile shows high scores in technical level and reliability, with moderate quantity and quality of information. This reflects a highly specialized webinar that prioritizes depth and credibility over breadth, suitable for an expert audience.

Reliability 8/10